Cooley-Cutter Biconical Disc Heart Valve

Object Details

Description (Brief)
The Cooley-Cutter heart valve was designed in the 1960s by Denton A. Cooley, MD, in collaboration with Cutter Laboratories, and introduced for clinical use in 1971. This is a non-tilting disc valve with a pyrolyte poppet and a double set of titanium struts. Non-tilting disc valves were advantageous with regards to limiting regurgitation of blood. They had a low profile design and were easy to implant. Issues with this valve included thromboembolic complications, higher rates of hemolysis, strut wear due to the hard pyrolytic and soft titanium, and significant turbulence in blood flow. In 1977, there were two reported cases of strut fracture--a failure that can be attributed to the "differential hardness" in the materials being used. This resulted in its discontinuation by 1978. The majority of these valves were implanted at the Texas Heart Institute in Houston. Dr. Cooley gave Mr. Villafaña several valves for his collection including this Cooley-Cutter artificial heart valve.
Dr. Denton Cooley’s (1920- ) career parallels the development of heart surgery from its beginnings in the 1940s and 1950s. He was an intern for Dr. Alfred Blalock (1899-1964) who with Dr. Helen Taussig (1898-1986), were the first doctors to correct malformations of the heart by reconstructing the valves (Blalock-Taussig Operation.) Dr. Cooley considered this breakthrough, "the dawn of heart surgery." He received his medical training at Johns Hopkins University School of Medicine in 1944, and started a practice at Baylor College in Houston, TX.
Location
Currently not on view
Data Source
National Museum of American History
maker
Cutter Laboratories, Inc.
date made
after 1973
Credit Line
Gift of Manuel Villafaña
Physical Description
titanium (valve material)
cloth (valve material)
plastic (valve material)
pyrolytic carbon (valve material)
Measurements
overall: 3.5 cm x 2.6 cm; 1 3/8 in x 1 1/32 in
Object Name
cardiology
artificial heart valve
Cooley-Cutter Biconical Valve, 1973
There are restrictions for re-using this image. For more information, visit the Smithsonian's Terms of Use page .
International media Interoperability Framework
IIIF provides researchers rich metadata and media viewing options for comparison of works across cultural heritage collections. Visit the IIIF page to learn more.
View manifest View in Mirador Viewer

Link to Smithsonian homepage

  • About
  • Terms of Use
  • Privacy
  • YouTube
  • Twitter
Back to Top